| Bindings for a fan connected to the PWM lines
 | |
| 
 | |
| Required properties:
 | |
| - compatible	: "pwm-fan"
 | |
| - pwms		: the PWM that is used to control the PWM fan
 | |
| - cooling-levels      : PWM duty cycle values in a range from 0 to 255
 | |
| 			which correspond to thermal cooling states
 | |
| 
 | |
| Example:
 | |
| 	fan0: pwm-fan {
 | |
| 		compatible = "pwm-fan";
 | |
| 		cooling-min-state = <0>;
 | |
| 		cooling-max-state = <3>;
 | |
| 		#cooling-cells = <2>;
 | |
| 		pwms = <&pwm 0 10000 0>;
 | |
| 		cooling-levels = <0 102 170 230>;
 | |
| 	};
 | |
| 
 | |
| 	thermal-zones {
 | |
| 		cpu_thermal: cpu-thermal {
 | |
| 			     thermal-sensors = <&tmu 0>;
 | |
| 			     polling-delay-passive = <0>;
 | |
| 			     polling-delay = <0>;
 | |
| 			     trips {
 | |
| 					cpu_alert1: cpu-alert1 {
 | |
| 						    temperature = <100000>; /* millicelsius */
 | |
| 						    hysteresis = <2000>; /* millicelsius */
 | |
| 						    type = "passive";
 | |
| 					};
 | |
| 			     };
 | |
| 			     cooling-maps {
 | |
| 					map0 {
 | |
| 						    trip = <&cpu_alert1>;
 | |
| 						    cooling-device = <&fan0 0 1>;
 | |
| 					};
 | |
| 			     };
 | |
| 		};
 | 