Tegra124 SOCTHERM thermal management system
 | 
						|
 | 
						|
The SOCTHERM IP block contains thermal sensors, support for polled
 | 
						|
or interrupt-based thermal monitoring, CPU and GPU throttling based
 | 
						|
on temperature trip points, and handling external overcurrent
 | 
						|
notifications. It is also used to manage emergency shutdown in an
 | 
						|
overheating situation.
 | 
						|
 | 
						|
Required properties :
 | 
						|
- compatible : For Tegra124, must contain "nvidia,tegra124-soctherm".
 | 
						|
  For Tegra132, must contain "nvidia,tegra132-soctherm".
 | 
						|
  For Tegra210, must contain "nvidia,tegra210-soctherm".
 | 
						|
- reg : Should contain at least 2 entries for each entry in reg-names:
 | 
						|
  - SOCTHERM register set
 | 
						|
  - Tegra CAR register set: Required for Tegra124 and Tegra210.
 | 
						|
  - CCROC register set: Required for Tegra132.
 | 
						|
- reg-names :  Should contain at least 2 entries:
 | 
						|
  - soctherm-reg
 | 
						|
  - car-reg
 | 
						|
  - ccroc-reg
 | 
						|
- interrupts : Defines the interrupt used by SOCTHERM
 | 
						|
- clocks : Must contain an entry for each entry in clock-names.
 | 
						|
  See ../clocks/clock-bindings.txt for details.
 | 
						|
- clock-names : Must include the following entries:
 | 
						|
  - tsensor
 | 
						|
  - soctherm
 | 
						|
- resets : Must contain an entry for each entry in reset-names.
 | 
						|
  See ../reset/reset.txt for details.
 | 
						|
- reset-names : Must include the following entries:
 | 
						|
  - soctherm
 | 
						|
- #thermal-sensor-cells : Should be 1. See ./thermal.txt for a description
 | 
						|
    of this property. See <dt-bindings/thermal/tegra124-soctherm.h> for a
 | 
						|
    list of valid values when referring to thermal sensors.
 | 
						|
- throttle-cfgs: A sub-node which is a container of configuration for each
 | 
						|
    hardware throttle events. These events can be set as cooling devices.
 | 
						|
  * throttle events: Sub-nodes must be named as "light" or "heavy".
 | 
						|
      Properties:
 | 
						|
      - nvidia,priority: Each throttles has its own throttle settings, so the
 | 
						|
        SW need to set priorities for various throttle, the HW arbiter can select
 | 
						|
        the final throttle settings.
 | 
						|
        Bigger value indicates higher priority, In general, higher priority
 | 
						|
        translates to lower target frequency. SW needs to ensure that critical
 | 
						|
        thermal alarms are given higher priority, and ensure that there is
 | 
						|
        no race if priority of two vectors is set to the same value.
 | 
						|
        The range of this value is 1~100.
 | 
						|
      - nvidia,cpu-throt-percent: This property is for Tegra124 and Tegra210.
 | 
						|
        It is the throttling depth of pulse skippers, it's the percentage
 | 
						|
        throttling.
 | 
						|
      - nvidia,cpu-throt-level: This property is only for Tegra132, it is the
 | 
						|
        level of pulse skippers, which used to throttle clock frequencies. It
 | 
						|
        indicates cpu clock throttling depth, and the depth can be programmed.
 | 
						|
        Must set as following values:
 | 
						|
        TEGRA_SOCTHERM_THROT_LEVEL_LOW, TEGRA_SOCTHERM_THROT_LEVEL_MED
 | 
						|
        TEGRA_SOCTHERM_THROT_LEVEL_HIGH, TEGRA_SOCTHERM_THROT_LEVEL_NONE
 | 
						|
      - #cooling-cells: Should be 1. This cooling device only support on/off state.
 | 
						|
        See ./thermal.txt for a description of this property.
 | 
						|
 | 
						|
Note:
 | 
						|
- the "critical" type trip points will be set to SOC_THERM hardware as the
 | 
						|
shut down temperature. Once the temperature of this thermal zone is higher
 | 
						|
than it, the system will be shutdown or reset by hardware.
 | 
						|
- the "hot" type trip points will be set to SOC_THERM hardware as the throttle
 | 
						|
temperature. Once the the temperature of this thermal zone is higher
 | 
						|
than it, it will trigger the HW throttle event.
 | 
						|
 | 
						|
Example :
 | 
						|
 | 
						|
	soctherm@700e2000 {
 | 
						|
		compatible = "nvidia,tegra124-soctherm";
 | 
						|
		reg = <0x0 0x700e2000 0x0 0x600  /* SOC_THERM reg_base */
 | 
						|
			0x0 0x60006000 0x0 0x400 /* CAR reg_base */
 | 
						|
		reg-names = "soctherm-reg", "car-reg";
 | 
						|
		interrupts = <GIC_SPI 48 IRQ_TYPE_LEVEL_HIGH>;
 | 
						|
		clocks = <&tegra_car TEGRA124_CLK_TSENSOR>,
 | 
						|
			<&tegra_car TEGRA124_CLK_SOC_THERM>;
 | 
						|
		clock-names = "tsensor", "soctherm";
 | 
						|
		resets = <&tegra_car 78>;
 | 
						|
		reset-names = "soctherm";
 | 
						|
 | 
						|
		#thermal-sensor-cells = <1>;
 | 
						|
 | 
						|
		throttle-cfgs {
 | 
						|
			/*
 | 
						|
			 * When the "heavy" cooling device triggered,
 | 
						|
			 * the HW will skip cpu clock's pulse in 85% depth
 | 
						|
			 */
 | 
						|
			throttle_heavy: heavy {
 | 
						|
				nvidia,priority = <100>;
 | 
						|
				nvidia,cpu-throt-percent = <85>;
 | 
						|
 | 
						|
				#cooling-cells = <1>;
 | 
						|
			};
 | 
						|
 | 
						|
			/*
 | 
						|
			 * When the "light" cooling device triggered,
 | 
						|
			 * the HW will skip cpu clock's pulse in 50% depth
 | 
						|
			 */
 | 
						|
			throttle_light: light {
 | 
						|
				nvidia,priority = <80>;
 | 
						|
				nvidia,cpu-throt-percent = <50>;
 | 
						|
 | 
						|
				#cooling-cells = <1>;
 | 
						|
			};
 | 
						|
 | 
						|
			/*
 | 
						|
			 * If these two devices are triggered in same time, the HW throttle
 | 
						|
			 * arbiter will select the highest priority as the final throttle
 | 
						|
			 * settings to skip cpu pulse.
 | 
						|
			 */
 | 
						|
		};
 | 
						|
	};
 | 
						|
 | 
						|
Example: referring to Tegra132's "reg", "reg-names" and "throttle-cfgs" :
 | 
						|
 | 
						|
	soctherm@700e2000 {
 | 
						|
		compatible = "nvidia,tegra132-soctherm";
 | 
						|
		reg = <0x0 0x700e2000 0x0 0x600  /* SOC_THERM reg_base */
 | 
						|
			0x0 0x70040000 0x0 0x200>; /* CCROC reg_base */;
 | 
						|
		reg-names = "soctherm-reg", "ccroc-reg";
 | 
						|
 | 
						|
		throttle-cfgs {
 | 
						|
			/*
 | 
						|
			 * When the "heavy" cooling device triggered,
 | 
						|
			 * the HW will skip cpu clock's pulse in HIGH level
 | 
						|
			 */
 | 
						|
			throttle_heavy: heavy {
 | 
						|
				nvidia,priority = <100>;
 | 
						|
				nvidia,cpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_HIGH>;
 | 
						|
 | 
						|
				#cooling-cells = <1>;
 | 
						|
			};
 | 
						|
 | 
						|
			/*
 | 
						|
			 * When the "light" cooling device triggered,
 | 
						|
			 * the HW will skip cpu clock's pulse in MED level
 | 
						|
			 */
 | 
						|
			throttle_light: light {
 | 
						|
				nvidia,priority = <80>;
 | 
						|
				nvidia,cpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_MED>;
 | 
						|
 | 
						|
				#cooling-cells = <1>;
 | 
						|
			};
 | 
						|
 | 
						|
			/*
 | 
						|
			 * If these two devices are triggered in same time, the HW throttle
 | 
						|
			 * arbiter will select the highest priority as the final throttle
 | 
						|
			 * settings to skip cpu pulse.
 | 
						|
			 */
 | 
						|
 | 
						|
		};
 | 
						|
	};
 | 
						|
 | 
						|
Example: referring to thermal sensors :
 | 
						|
 | 
						|
       thermal-zones {
 | 
						|
                cpu {
 | 
						|
                        polling-delay-passive = <1000>;
 | 
						|
                        polling-delay = <1000>;
 | 
						|
 | 
						|
                        thermal-sensors =
 | 
						|
                                <&soctherm TEGRA124_SOCTHERM_SENSOR_CPU>;
 | 
						|
 | 
						|
			trips {
 | 
						|
				cpu_shutdown_trip: shutdown-trip {
 | 
						|
					temperature = <102500>;
 | 
						|
					hysteresis = <1000>;
 | 
						|
					type = "critical";
 | 
						|
				};
 | 
						|
 | 
						|
				cpu_throttle_trip: throttle-trip {
 | 
						|
					temperature = <100000>;
 | 
						|
					hysteresis = <1000>;
 | 
						|
					type = "hot";
 | 
						|
				};
 | 
						|
			};
 | 
						|
 | 
						|
			cooling-maps {
 | 
						|
				map0 {
 | 
						|
					trip = <&cpu_throttle_trip>;
 | 
						|
					cooling-device = <&throttle_heavy 1 1>;
 | 
						|
				};
 | 
						|
			};
 | 
						|
                };
 | 
						|
	};
 |