.. SPDX-License-Identifier: GPL-2.0
 | 
						|
 | 
						|
============
 | 
						|
NET_FAILOVER
 | 
						|
============
 | 
						|
 | 
						|
Overview
 | 
						|
========
 | 
						|
 | 
						|
The net_failover driver provides an automated failover mechanism via APIs
 | 
						|
to create and destroy a failover master netdev and mananges a primary and
 | 
						|
standby slave netdevs that get registered via the generic failover
 | 
						|
infrastructrure.
 | 
						|
 | 
						|
The failover netdev acts a master device and controls 2 slave devices. The
 | 
						|
original paravirtual interface is registered as 'standby' slave netdev and
 | 
						|
a passthru/vf device with the same MAC gets registered as 'primary' slave
 | 
						|
netdev. Both 'standby' and 'failover' netdevs are associated with the same
 | 
						|
'pci' device. The user accesses the network interface via 'failover' netdev.
 | 
						|
The 'failover' netdev chooses 'primary' netdev as default for transmits when
 | 
						|
it is available with link up and running.
 | 
						|
 | 
						|
This can be used by paravirtual drivers to enable an alternate low latency
 | 
						|
datapath. It also enables hypervisor controlled live migration of a VM with
 | 
						|
direct attached VF by failing over to the paravirtual datapath when the VF
 | 
						|
is unplugged.
 | 
						|
 | 
						|
virtio-net accelerated datapath: STANDBY mode
 | 
						|
=============================================
 | 
						|
 | 
						|
net_failover enables hypervisor controlled accelerated datapath to virtio-net
 | 
						|
enabled VMs in a transparent manner with no/minimal guest userspace chanages.
 | 
						|
 | 
						|
To support this, the hypervisor needs to enable VIRTIO_NET_F_STANDBY
 | 
						|
feature on the virtio-net interface and assign the same MAC address to both
 | 
						|
virtio-net and VF interfaces.
 | 
						|
 | 
						|
Here is an example XML snippet that shows such configuration.
 | 
						|
::
 | 
						|
 | 
						|
  <interface type='network'>
 | 
						|
    <mac address='52:54:00:00:12:53'/>
 | 
						|
    <source network='enp66s0f0_br'/>
 | 
						|
    <target dev='tap01'/>
 | 
						|
    <model type='virtio'/>
 | 
						|
    <driver name='vhost' queues='4'/>
 | 
						|
    <link state='down'/>
 | 
						|
    <address type='pci' domain='0x0000' bus='0x00' slot='0x0a' function='0x0'/>
 | 
						|
  </interface>
 | 
						|
  <interface type='hostdev' managed='yes'>
 | 
						|
    <mac address='52:54:00:00:12:53'/>
 | 
						|
    <source>
 | 
						|
      <address type='pci' domain='0x0000' bus='0x42' slot='0x02' function='0x5'/>
 | 
						|
    </source>
 | 
						|
    <address type='pci' domain='0x0000' bus='0x00' slot='0x0b' function='0x0'/>
 | 
						|
  </interface>
 | 
						|
 | 
						|
Booting a VM with the above configuration will result in the following 3
 | 
						|
netdevs created in the VM.
 | 
						|
::
 | 
						|
 | 
						|
  4: ens10: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP group default qlen 1000
 | 
						|
      link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff
 | 
						|
      inet 192.168.12.53/24 brd 192.168.12.255 scope global dynamic ens10
 | 
						|
         valid_lft 42482sec preferred_lft 42482sec
 | 
						|
      inet6 fe80::97d8:db2:8c10:b6d6/64 scope link
 | 
						|
         valid_lft forever preferred_lft forever
 | 
						|
  5: ens10nsby: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc fq_codel master ens10 state UP group default qlen 1000
 | 
						|
      link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff
 | 
						|
  7: ens11: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq master ens10 state UP group default qlen 1000
 | 
						|
      link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff
 | 
						|
 | 
						|
ens10 is the 'failover' master netdev, ens10nsby and ens11 are the slave
 | 
						|
'standby' and 'primary' netdevs respectively.
 | 
						|
 | 
						|
Live Migration of a VM with SR-IOV VF & virtio-net in STANDBY mode
 | 
						|
==================================================================
 | 
						|
 | 
						|
net_failover also enables hypervisor controlled live migration to be supported
 | 
						|
with VMs that have direct attached SR-IOV VF devices by automatic failover to
 | 
						|
the paravirtual datapath when the VF is unplugged.
 | 
						|
 | 
						|
Here is a sample script that shows the steps to initiate live migration on
 | 
						|
the source hypervisor.
 | 
						|
::
 | 
						|
 | 
						|
  # cat vf_xml
 | 
						|
  <interface type='hostdev' managed='yes'>
 | 
						|
    <mac address='52:54:00:00:12:53'/>
 | 
						|
    <source>
 | 
						|
      <address type='pci' domain='0x0000' bus='0x42' slot='0x02' function='0x5'/>
 | 
						|
    </source>
 | 
						|
    <address type='pci' domain='0x0000' bus='0x00' slot='0x0b' function='0x0'/>
 | 
						|
  </interface>
 | 
						|
 | 
						|
  # Source Hypervisor
 | 
						|
  #!/bin/bash
 | 
						|
 | 
						|
  DOMAIN=fedora27-tap01
 | 
						|
  PF=enp66s0f0
 | 
						|
  VF_NUM=5
 | 
						|
  TAP_IF=tap01
 | 
						|
  VF_XML=
 | 
						|
 | 
						|
  MAC=52:54:00:00:12:53
 | 
						|
  ZERO_MAC=00:00:00:00:00:00
 | 
						|
 | 
						|
  virsh domif-setlink $DOMAIN $TAP_IF up
 | 
						|
  bridge fdb del $MAC dev $PF master
 | 
						|
  virsh detach-device $DOMAIN $VF_XML
 | 
						|
  ip link set $PF vf $VF_NUM mac $ZERO_MAC
 | 
						|
 | 
						|
  virsh migrate --live $DOMAIN qemu+ssh://$REMOTE_HOST/system
 | 
						|
 | 
						|
  # Destination Hypervisor
 | 
						|
  #!/bin/bash
 | 
						|
 | 
						|
  virsh attach-device $DOMAIN $VF_XML
 | 
						|
  virsh domif-setlink $DOMAIN $TAP_IF down
 |