31 lines
		
	
	
		
			1.0 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
			
		
		
	
	
			31 lines
		
	
	
		
			1.0 KiB
		
	
	
	
		
			Plaintext
		
	
	
	
	
	
Lantiq XWAY SoC RCU reset controller binding
 | 
						|
============================================
 | 
						|
 | 
						|
This binding describes a reset-controller found on the RCU module on Lantiq
 | 
						|
XWAY SoCs.
 | 
						|
 | 
						|
This node has to be a sub node of the Lantiq RCU block.
 | 
						|
 | 
						|
-------------------------------------------------------------------------------
 | 
						|
Required properties:
 | 
						|
- compatible		: Should be one of
 | 
						|
				"lantiq,danube-reset"
 | 
						|
				"lantiq,xrx200-reset"
 | 
						|
- reg			: Defines the following sets of registers in the parent
 | 
						|
			  syscon device
 | 
						|
			- Offset of the reset set register
 | 
						|
			- Offset of the reset status register
 | 
						|
- #reset-cells		: Specifies the number of cells needed to encode the
 | 
						|
			  reset line, should be 2.
 | 
						|
			  The first cell takes the reset set bit and the
 | 
						|
			  second cell takes the status bit.
 | 
						|
 | 
						|
-------------------------------------------------------------------------------
 | 
						|
Example for the reset-controllers on the xRX200 SoCs:
 | 
						|
	reset0: reset-controller@10 {
 | 
						|
		compatible = "lantiq,xrx200-reset";
 | 
						|
		reg <0x10 0x04>, <0x14 0x04>;
 | 
						|
 | 
						|
		#reset-cells = <2>;
 | 
						|
	};
 |